This post covers the firmware, calibration and server side of the pneumatic water level sensor project. The hardware design (MPX2050DP, INA333, MCP3426, PCB) is described in the companion post: Pneumatic Water Level Sensor – Hardware. The full discussion thread with source files is on mikrocontroller.net.
The code was developed entirely with AI assistance (Claude) and reviewed by me. It runs on MicroPython on the Raspberry Pi Pico W.
Unterstützen
Wir sind unabhängig schalten keine Werbung und benutzen keine Affiliation Links. Wenn Du uns unterstützen möchtest, ist dies hier möglich: ♥
1. Firmware Overview
The software is split into two independent projects: the Pico W firmware and the Raspberry Pi server.
The Pico W runs MicroPython and consists of seven files:
epd_driver.pyis the unmodified low-level driver for the Waveshare 2.9″ e-Paper display.config.pyholds all hardware constants and calibration coefficients (CAL_A, CAL_B) as a single source of truth.sensors.pyencapsulates the MCP9808 temperature sensor and MCP3426 ADC behind clean driver classes.display_ui.pyrenders all four screen layouts — main view, 30-day graph, admin menu and boot splash — in native portrait mode (128×296 px).button.pyimplements debounced multi-tap detection (1 tap = instant measurement, 2 taps = graph, 3 taps = admin).storage.pymanages three JSON files on the Pico flash: calibration parameters, 60-day daily aggregates for the graph, and a transmit queue for measurements not yet delivered to the Pi.wifi.pyhandles Wi-Fi connection, NTP time sync (Europe/Berlin) and HTTP communication with the Pi server;.envcredentials are loaded from .env file.main.pyties everything together: hardware initialisation, the hourly measurement loop, the display state machine and periodic polling for remote trigger requests from the Pi.
The Raspberry Pi runs a Flask/Gunicorn server (app.py) on port 5000, installed as a systemd service via install.sh.
data_store.pypersists every measurement in a plain CSV file — no database required — making the data directly portable and exportable.- The web front-end (
index.html,style.css,chart_app.js) provides a live dashboard with current water level and temperature, a historical chart with selectable time range, and a button to trigger an instant measurement remotely.
2. Installation
2.1 Pico W Setup
- Copy all files from the
picofolder to the Pico W using mpremote:
mpremote connect auto fs cp FILENAME.py :
- Create a
.envfile with your credentials and copy it to the Pico:
WIFI_SSID=YourNetwork
WIFI_PASS=YourPassword
PI_HOST=192.168.X.XX
PI_PORT=5000
2.2 Raspberry Pi Server Setup
- Copy all files from
pifolder to the Raspberry Pi. - Run
install.shto set up the Flask server and SQLite database.
3. ADC Configuration
The MCP3426 is configured as follows:
ADC_CFG = 0x88 # Channel 1, One-Shot, 16-bit, PGA ×1
Each measurement is averaged 32 times (integer summation, single float conversion at the end). This reduces noise by a factor of √32 ≈ 5.7. ADC resolution: 16-bit / 62.5 µV per LSB.
4. Calibration
4.1 Procedure
The calibration takes 5 measurement points at known reference pressures and computes the coefficients a and b via least-squares linear regression:
Pressure [kPa] = a · ADC [mV] + b
Reference pressures are applied using a precision mmHg manometer. Conversion: 1 mmHg = 1.35951 cm H₂O.
Calibration points used: 0 / 100 / 160 / 220 / 300 mmHg
4.2 Results
a = 0.037497 kPa/mV
b = −0.343484 kPa
Max error = 2.45 cm
Effective sensitivity: 26.9 mV/kPa (99.2% of theoretical)
The achieved maximum error of 2.45 cm over a 470 cm range exceeds the design target of 5 cm and corresponds to a relative accuracy of better than 0.5%.
4.3 Temperature Compensation
The MPX2050DP has on-chip temperature compensation (±1% VFSS over 0–85°C). At a 20°C temperature swing the residual error is under 0.4 cm – no software compensation is required. The MCP9808 temperature sensor on the board is available for logging and future use.
5. Display and User Interface
The Waveshare 2.9″ e-Paper display (128×296 px, SPI) shows the current water level, timestamp and last measurement result. Button interactions:
- 1× press: Trigger immediate measurement
- 2× press: Show 30-day graph (planned)
- 3× press: Admin menu (planned)
6. Wi-Fi and Server
Once per hour the Pico W connects to Wi-Fi and transmits the measurement to a Raspberry Pi running a lightweight Flask server with SQLite storage. The server provides:
- Real-time display of the current water level
- 30-day chart
- Annual archive
- CSV export
Calibration data and measurements are stored on the Pico flash (JSON), so the device survives a power cycle without losing its configuration.
7. Outlook
- Complete display menu with 30-day graph and admin mode
- Persistent storage for all historical measurements on Pico flash
- Web interface improvements: full year archive view, alerting
- Housing build (report to follow)
Related Posts
- Pneumatic Water Level Sensor – Hardware (MPX2050DP, INA333, MCP3426, PCB)
- Garden well build guide
- DN150 stainless steel well head
- HL DSK8 pump controller repair
Unterstützen
Wir sind unabhängig schalten keine Werbung und benutzen keine Affiliation Links. Wenn Du uns unterstützen möchtest, ist dies hier möglich: ♥